Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38513837

RESUMEN

BACKGROUND: Cyclophilins are ubiquitous panallergens whose epidemiologic, diagnostic, and clinical relevance is largely unknown and whose sensitization is rarely examined in routine allergy practice. OBJECTIVE: We investigated the epidemiologic, diagnostic, and clinical relevance of cyclophilins in seasonal allergic rhinitis and its comorbidities. METHODS: We examined a random sample of 253 (25%) of 1263 Italian children with seasonal allergic rhinitis from the Panallergens in Pediatrics (PAN-PED) cohort with characterized disease phenotypes. Nested studies of sensitization prevalence, correlation, and allergen extract inhibition were performed in patients sensitized to birch pollen extract but lacking IgE to Bet v 1/2/4 (74/1263) or with highest serum level of IgE to Bet v 1 (26/1263); and in patients with sensitization to various extracts (ragweed, mugwort, pellitory, Plantago, and plane tree), but not to their respective major allergenic molecule, profilins, and polcalcins. IgE to cyclophilin was detected with recombinant Bet v 7, and extract inhibition tests were performed with the same rBet v 7. RESULTS: IgE to rBet v 7 was detected in 43 (17%) of 253 patients. It was associated with asthma (P < .028) and oral allergy syndrome (P < .017) in univariate but not multivariate analysis adjusted for IgE to profilins (Phl p 12), PR-10s (Bet v 1), and lipid transfer proteins (Pru p 3). IgE to rBet v 7 was also highly prevalent (47/74, 63%) among patients with unexplained sensitization to birch pollen extract. In patients with unexplained sensitization to ragweed, mugwort, pellitory, Plantago and plane tree pollen, the levels of IgE to those extracts correlated with the levels of IgE to rBet v 7, and they were also significantly inhibited by rBet v 7 (inhibition range 45%-74%). CONCLUSIONS: IgE sensitization to cyclophilin is frequent in pollen-allergic patients living in temperate areas and can produce "false" positive outcomes in skin prick and IgE tests to pollen extracts. Molecular diagnostic guidelines should include this panallergen family.

2.
Clin Exp Allergy ; 54(3): 195-206, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38234127

RESUMEN

BACKGROUND: IgE antibodies to cross-reactive carbohydrate determinants (CCD) are usually clinically irrelevant but they can be a cause of false positive outcomes of allergen-specific IgE tests in vitro. Their prevalence and levels have been so far cross-sectionally examined among adult allergic patients and much less is known about their origins and relevance in childhood. METHODS: We examined CCD with a cross-sectional approach in 1263 Italian pollen allergic children (Panallergen in Paediatrics, PAN-PED), as well as with a longitudinal approach in 612 German children (Multicenter Allergy Study, MAS), whose cutaneous and IgE sensitization profile to a broad panel of allergen extracts and molecules was already known. The presence and levels of IgE to CCD were examined in the sera of both cohorts using bromelain (MUXF3) as reagent and a novel chemiluminescence detection system, operating in a solid phase of fluorescently labelled and streptavidin-coated paramagnetic microparticles (NOVEOS, HYCOR, USA). RESULTS: IgE to CCD was found in 22% of the Italian pollen allergic children, mainly in association with an IgE response to grass pollen. Children with IgE to CCD had higher total IgE levels and were sensitized to more allergenic molecules of Phleum pratense than those with no IgE to CCD. Among participants of the German MAS birth cohort study, IgE to CCD emerged early in life (even at pre-school age), with IgE sensitization to group 1 and 4 allergen molecules of grasses, and almost invariably persisted over the full observation period. CONCLUSIONS: Our results contribute to dissect the immunological origins, onset, evolution and risk factors of CCD-sIgE response in childhood, and raise the hypothesis that group 1 and/or 4 allergen molecules of grass pollen are major inducers of these antibodies through an antigen-specific, T-B cell cognate interaction.


Asunto(s)
Hipersensibilidad , Inmunoglobulina E , Adulto , Humanos , Niño , Preescolar , Estudios de Cohortes , Prevalencia , Alérgenos , Carbohidratos , Factores de Riesgo , Reacciones Cruzadas
3.
ERJ Open Res ; 10(1)2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38226060

RESUMEN

Introduction: Wheezing is common in preschool children and its clinical assessment often challenging for caretakers. This study aims to evaluate the impact of a novel digital wheeze detector (WheezeScan™) on disease control in a home care setting. Methods: A multicentre randomised open-label controlled trial was conducted in Berlin, Istanbul and London. Participants aged 4-84 months with a doctor's diagnosis of recurrent wheezing in the past 12 months were included. While the control group followed usual care, the intervention group received the WheezeScan™ for at-home use for 120 days. Parents completed questionnaires regarding their child's respiratory symptoms, disease-related and parental quality of life, and caretaker self-efficacy at baseline (T0), 90 days (T1) and 4 months (T2). Results: A total of 167 children, with a mean±sd age of 3.2±1.6 years, were enrolled in the study (intervention group n=87; control group n=80). There was no statistically significant difference in wheeze control assessed by TRACK (mean difference 3.8, 95% CI -2.3-9.9; p=0.2) at T1 between treatment groups (primary outcome). Children's and parental quality of life and parental self-efficacy were comparable between both groups at T1. The evaluation of device usability and perception showed that parents found it useful. Conclusion: In the current study population, the wheeze detector did not show significant impact on the home management of preschool wheezing. Hence, further research is needed to better understand how the perception and usage behaviour may influence the clinical impact of a digital support.

4.
Pediatr Allergy Immunol ; 34(6): e13966, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37366207

RESUMEN

Hirst pollen traps and operator pollen recognition are worldwide used by aerobiologists, providing essential services for the diagnosis and monitoring of allergic patients. More recently, semiautomated or fully automated detector systems have been developed, which facilitate prediction of pollen exposure and risk for the individual patient. In parallel, smartphone apps consisting of short questionnaires filled in daily by the patient/user provide daily scores, time trajectories, and descriptive reports of the severity of respiratory allergies in patients with pollen allergy. The usual scientific and clinical approach to this matter is to monitor the environment (pollen concentration) in order to predict the risk of symptoms (allergic rhinitis) in a population. We discuss here the opposite, contraintuitive possibility, that is, the use of e-diaries to collect daily information of mono-sensitized pollen-allergic patients in order to predict the clinically efficient airborne exposure to a given pollen, area, and time period. In line with the "Patient as Sensor" concept, proposed in 2013 by Bernd Resch, the "allergic nose" may be used as a pollen detector in addition to existing calibrated hardware sensors, namely the pollen stations, thus contributing with individual measurements, sensations, and symptoms' perception. The target of this review is to present a novel concept of pollen monitoring based on "pollen-detector" patients to inspire future cooperative studies aimed at investigating and hopefully validating our hypothesis.


Asunto(s)
Aplicaciones Móviles , Rinitis Alérgica Estacional , Rinitis Alérgica , Humanos , Polen , Rinitis Alérgica Estacional/diagnóstico , Rinitis Alérgica Estacional/epidemiología , Nariz , Rinitis Alérgica/diagnóstico , Alérgenos
5.
Biomedicines ; 11(5)2023 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-37239049

RESUMEN

Opposite to other immunoglobulin (Ig) classes and subclasses, there is no consensus on the definition of normal levels of serum total IgE. However, longitudinal studies on birth cohorts produced growth charts of total IgE levels in helminth-free and never atopic children and defining the normal ranges of total serum IgE concentration at the individual, rather than population, level. Accordingly, very 'low IgE producers' (i.e., children whose tIgE level belong to the lowest percentiles) became atopic while keeping their total IgE levels in a range considered 'normal' if compared to the general age-matched population but 'abnormally high' if projected on the tIgE growth chart against the trajectory of that child's own percentile levels. In 'low IgE producers', the IgE-specific activity, i.e., the ratio between allergen-specific and total IgE, is more important than the absolute specific IgE levels to confirm causality between allergen exposure and allergic symptoms. Patients with allergic rhinitis or peanut anaphylaxis but low or undetectable allergen-specific IgE levels must therefore be reconsidered considering their total IgE levels. Low IgE producers have been also associated with common variable immunodeficiency, lung diseases, and malignancies. A few epidemiological studies have shown a higher risk of malignancies in very low IgE producers, leading to a debated hypothesis proposing a novel, evolutionistic-relevant function for IgE antibodies for antitumor immune surveillance.

7.
Allergol Select ; 6: 293-298, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36523960

RESUMEN

In the recent past, digital healthcare technologies are experiencing a significant leap in development, with an additional unforeseen acceleration in implementation due to the SARS-CoV-2 pandemic. The increased use of mobile applications as well as communication technologies to search for services and support hold particular advantages for the management of chronic diseases requiring medium- to long-term treatments and regular follow-up visits. Allergen immunotherapy (AIT), requiring regular application of treatment, represents an optimal scenario for feasible digital support. From patient stratification and care pathways, over personalized decision support for complex clinical scenarios, towards a close and flexible patient-doctor communication in blended care settings: the current article summarizes the latest knowledge on the use and potential of digital health technologies in the area of AIT .

8.
Pediatr Allergy Immunol ; 33(11): e13867, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36433848

RESUMEN

BACKGROUND: In vitro immunoglobulin E (IgE) tests can be better standardized if based on molecules rather than extracts. However, singleplex screening tests for respiratory or food allergies are still based on extracts only. TARGET: To validate a novel singleplex IgE screening test for respiratory allergies, based on a mix of major allergenic molecules Der p 1, Der p 2, Fel d 1, Can f 1, Can f 2, Can f 3, Can f 5, Bet v 1, Phl p 1, and Art v 1 (Molecular SX01, NOVEOS, HYCOR, USA), and requiring only four microliters (µl) of serum. METHODS: We examined six subsets of sera from participants of the German Multicenter Allergy Study (MAS) birth cohort enrolling 1314 newborns during 1990: (1) monosensitized (n = 58); (2) polysensitized (n = 24); (3) nonsensitized, with total IgE levels above (n = 24) or (4) below (n = 24) 300 kU/L; (5) sensitized to milk and/or egg but not to airborne allergens (n = 24); and (6) sera of children aged ≤5 years at their earliest IgE monosensitization to airborne allergens (n = 41). Sera were analyzed with the novel molecular SX01 test (NOVEOS) and with three categories of comparators: ImmunoCAP Phadiatop SX01, extracts, and molecules of D. pteronyssinus, cat, dog, grass, and birch. Sensitivity, specificity, positive and negative predictive values were calculated. Quantitative interrelationships were determined using Spearman's rank-order correlation coefficient and Bland-Altmann plots. RESULTS: The molecular SX01 test predicted the outcome of IgE tests based on molecules, extracts, or Phadiatop in 188 (96.4%), 171 (87.7%), and 171 (87.7%) of the 195 sera, respectively. Accordingly, sensitivity was 93.5%, 89.0%, and 82.4%, whereas specificity was 100%, 97.6%, and 96.1% when compared with molecular, extract, and Phadiatop tests, respectively. Inconsistent outcomes were largely confined to sera with IgE-Ab levels around the cutoff value of 0.35 kU/L, except for 5/195 (2.5%) sera, containing high levels of IgE to Phl p 5 and/or Alt a 1 only. IgE levels measured by the molecular SX01 test and with IgE tests to molecules, extracts, and Phadiatop were highly correlated (rho 0.90; p < .001), (rho 0.87, p < .001), (rho 0.84, p < .001), respectively. The novel molecular SX01 test detected IgE-Ab in 27/28 (sensitivity 96.4%) of the sera of preschool children at their earliest IgE sensitization to the same molecules. DISCUSSION: Our study validates the prototype of a novel category of IgE test, based on molecular mixes. The test's rather good precision and accuracy in early screening IgE sensitization to airborne allergens in German children may be further improved by adding a few other molecules, such as Phl p 5 and Alt a 1.


Asunto(s)
Hipersensibilidad a los Alimentos , Hipersensibilidad Respiratoria , Humanos , Perros , Animales , Alérgenos , Inmunoglobulina E , Dermatophagoides pteronyssinus
9.
Pediatr Allergy Immunol ; 33(7): e13829, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35871456

RESUMEN

BACKGROUND: The Dermatophagoides pteronyssinus molecule Der p 23 is a major allergen whose clinical relevance has been shown in cross-sectional studies. We longitudinally analysed the trajectory of Der p 23-specific IgE antibody (sIgE) levels throughout childhood and youth, their early-life determinants and their clinical relevance for allergic rhinitis and asthma. METHODS: We obtained sera and clinical data of 191 participants of the German Multicentre Allergy Study, a prospective birth cohort. Serum samples from birth to 20 years of age with sIgE reactivity to Der p 23 in a customised semiquantitative microarray were newly analysed with a singleplex quantitative assay. Early mite exposure was assessed by measuring the average content of Der p 1 in house dust at 6 and 18 months. RESULTS: Der p 23-sIgE levels were detected at least once in 97/191 participants (51%). Prevalence of Der p 23 sensitisation and mean sIgE levels increased until age 10 years, plateaued until age 13 years and were lowest at age 20 years. Asthma, allergic rhinitis (AR) and atopic dermatitis (AD) were more prevalent in Der p 23-sensitised children, including those with monomolecular but persistent sensitisation (11/97, 11%). A higher exposure to mites in infancy and occurrence of AD before 5 years of age preceded the onset of Der p 23 sensitisation, which in turn preceded a higher incidence of asthma. CONCLUSIONS: Der p 23 sensitisation peaks in late childhood and then decreases. It is preceded by early mite exposure and AD. Asthma and AR can occur in patients persistently sensitised to Der p 23 as the only mite allergen, suggesting the inclusion of molecular testing of Der p 23-sIgE for subjects with clinical suspicion of HDM allergy but without sIgE to other major D.pt. allergens.


Asunto(s)
Asma , Dermatitis Atópica , Ácaros , Rinitis Alérgica , Adolescente , Adulto , Alérgenos , Animales , Antígenos Dermatofagoides , Cohorte de Nacimiento , Niño , Estudios de Cohortes , Estudios Transversales , Humanos , Inmunoglobulina E , Estudios Prospectivos , Adulto Joven
10.
JMIR Mhealth Uhealth ; 10(6): e31491, 2022 06 03.
Artículo en Inglés | MEDLINE | ID: mdl-35657659

RESUMEN

BACKGROUND: Mobile health technologies enable allergists to monitor disease trends by collecting daily patient-reported outcomes of allergic rhinitis. To this end, patients with allergies are usually required to enter their symptoms and medication repetitively over long time periods, which may present a risk to data completeness and quality in the case of insufficient effort reporting. Completeness of patient's recording is easily measured. In contrast, the intrinsic quality and accuracy of the data entered by the patients are more elusive. OBJECTIVE: The aim of this study was to explore the association of adherence to digital symptom recording with a predefined set of parameters of the patient-generated symptom and medication scores and to identify parameters that may serve as proxy measure of the quality and reliability of the information recorded by the patient. METHODS: The @IT.2020 project investigates the diagnostic synergy of mobile health and molecular allergology in patients with seasonal allergic rhinitis. In its pilot phase, 101 children with seasonal allergic rhinitis were recruited in Rome and instructed to record their symptoms, medication intake, and general conditions daily via a mobile app (AllergyMonitor) during the relevant pollen season. We measured adherence to daily recording as the percentage of days with data recording in the observation period. We examined the patient's trajectories of 3 disease indices (Rhinoconjunctivitis Total Symptom Score [RTSS], Combined Symptom and Medication Score [CSMS], and Visual Analogue Scale [VAS]) as putative proxies of data quality with the following 4 parameters: (1) intravariation index, (2) percentage of zero values, (3) coefficient of variation, and (4) percentage of changes in trend. Lastly, we examined the relationship between adherence to recording and each of the 4 proxy measures. RESULTS: Adherence to recording ranged from 20% (11/56) to 100% (56/56), with 64.4% (65/101) and 35.6% (36/101) of the patients' values above (highly adherent patients) or below (low adherent patients) the threshold of 80%, respectively. The percentage of zero values, the coefficient of variation, and the intravariation index did not significantly change with the adherence to recording. By contrast, the proportion of changes in trend was significantly higher among highly adherent patients, independently from the analyzed score (RTSS, CSMS, and VAS). CONCLUSIONS: The percentage of changes in the trend of RTSS, CSMS, and VAS is a valuable candidate to validate the quality and accuracy of the data recorded by patients with allergic rhinitis during the pollen season. The performance of this parameter must be further investigated in real-life conditions before it can be recommended for routine use in apps and electronic diaries devoted to the management of patients with allergic rhinitis.


Asunto(s)
Aplicaciones Móviles , Rinitis Alérgica Estacional , Rinitis Alérgica , Niño , Humanos , Polen , Reproducibilidad de los Resultados , Rinitis Alérgica/diagnóstico , Rinitis Alérgica Estacional/diagnóstico , Rinitis Alérgica Estacional/tratamiento farmacológico
11.
Clin Transl Allergy ; 11(10): e12084, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34950450

RESUMEN

BACKGROUND: Patient-generated symptom and medication scores are essential for diagnostic and therapeutic decisions in seasonal allergic rhinitis (SAR). Previous studies have shown solid consistencies between different scores at population level in real-life data and trials. For clinicians, the evaluation of individual data quality over time is essential to decide whether to rely on these data in clinical decision-making. OBJECTIVE: To analyze the consistency of different symptom (SS) and symptom medication scores (SMSs) at individual level in two study cohorts with different characteristics and explore individual patient trajectories over time. METHODS: Within the pilot phase of the @IT.2020 project on diagnostic synergy of mobile health and molecular IgE assessment in patients with SAR, we analyzed data of 101 children and 93 adults with SAR and instructed them to record their symptoms and medication intake daily via the mobile app AllergyMonitor®. We then assessed the correlation between different SMS and a visual analogue scale (VAS) on the impact of allergy symptoms on daily life at population and individual level. RESULTS: At population level, the Rhinoconjunctivitis total symptom score (RTSS) correlated better with VAS than the combined symptom and medication score (CSMS). At individual level, consistency among RTSS and VAS was highly heterogeneous and unrelated to disease severity or adherence to recording. Similar heterogeneity was observed for CSMS and VAS. CONCLUSIONS: The correlation of clinical information provided by different disease severity scores based on data collected via electronic diaries (e-diaries), is sufficient at population level, but broadly heterogeneous for individual patients. Consistency of the recorded data must be examined for each patient before remotely collected information is used for clinical decision making.

12.
Pilot Feasibility Stud ; 7(1): 185, 2021 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-34627391

RESUMEN

BACKGROUND: Viral airway infections are a major reason for doctor's visits at pre-school age, especially when associated with wheezing. While proper treatment requires adequate recognition of airway obstruction, caretakers are often struggling with this judgment, consequently leading to insufficient or late treatment and an unnecessary discomfort of the patient. Digital technologies may serve to support parental decision taking. The aim of the present pilot study is to acquire data on the feasibility of recruitment and observation procedures for a randomized controlled trial on the impact of a digital wheeze detector in a home management setting of pre-school wheezing. METHODS: This single-armed pilot study enrolled patients with a doctor's diagnosis of wheezing aged 9 to 72 months. Participants were asked to use a digital wheeze detector (WheezeScan, Omron Healthcare, Japan) 2×/day for 30 days and record the child's respiratory symptoms, detection of wheezing, and medication intake via an electronic diary (eDiary) app. Demographic and clinical data were collected at the recruitment visit. The asthma control test and the Parent Asthma Management Self-Efficacy Scale (PAMSES) were assessed both, at recruitment and follow-up. RESULTS: Twenty families were recruited and completed the monitoring. All but one completed the follow-up after 30 days. The recruitment procedures were feasible, and adherence to daily monitoring reached an average of 81%. The use of the wheeze detector was rated as uncomplicated. Parents detected wheezing without digital support in only 22/708 (3.1%) of the recorded events. By contrast, the wheeze detector indicated an airway obstruction in 140/708 (19.8%) of the recordings. CONCLUSION: In parallel to feasible recruitment procedures, we observed good usability of the wheeze detection device and high adherence to eDiary recording. The positive outcomes show that the WheezeScan may empower parents by increasing their capacity for wheeze detection. This deserves to be investigated in a larger randomized controlled trial.

13.
Allergo J Int ; 30(6): 193-197, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34150465

RESUMEN

BACKGROUND: The severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) pandemic presented unprecedented challenges to both inpatient and outpatient care. In order to maintain good care under necessary contact restrictions, especially in the outpatient sector, the use of telemedical applications was demanded and promoted. The exploratory survey among members of the Association of German Allergists (AeDA) was intended to show how these were received among allergists in private practice. METHODS: The survey was restricted to actively practising members of the AeDA who had previously given their consent to receive such surveys (n = 437). They were invited by email to participate in a survey on the topic of "Telemedicine in everyday clinical practice in allergology". The survey included quantitative and qualitative questions on the use of telemedicine services before and during the pandemic and was conducted anonymously on the SoSci Survey platform. Participation was possible in the period from June to August 2020. RESULTS: In all, 76 specialists with additional qualification in allergology took part in the survey. Of these, 71 completed the full questionnaire. Before the start of the pandemic-related contact restrictions, 46.5% (33/71) stated that they had used telemedicine in their clinical practice. This number increased to 73.2% (52/71) after 31 January 2020. The largest increase (4.3% vs. 15.6%) was seen in the area of video consultations. Furthermore, 43/76 participants can imagine integrating telemedicine services into their daily clinical routine in the future. CONCLUSION: The use of telemedical services, especially video consultations, increased significantly during the SARS-CoV­2 pandemic in Germany. The majority of respondents perceive the implementation as positive and can imagine continuing to use telemedical methods after the end of the pandemic.

14.
Clin Exp Allergy ; 51(6): 821-828, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33759270

RESUMEN

BACKGROUND: Allergen immunotherapy (AIT) is the only disease-modifying treatment in patients with seasonal allergic rhinoconjunctivitis (SAR). Its efficacy depends on the precise identification of the triggering allergen. However, diagnostics based on retrospective clinical history and sensitization to whole extracts (SWE) often leads to equivocal results. OBJECTIVES: To assess the usability and impact of a recently established algorithm for a clinical decision support system (@IT2020-CDSS) for SAR and its diagnostic steps [anamnesis, SWE (skin prick test or serum IgE), component resolved diagnosis, CRD, and real-time digital symptom recording, eDiary] on doctor's AIT prescription decisions. METHODS: After educational training on the @IT2020-CDSS algorithm, 46 doctors (18 allergy specialists, AS, and 28 general practitioners, GP) expressed their hypothetical AIT prescription for 10 clinical index cases. Decisions were recorded repeatedly based on different steps of the algorithm. The usability and perceived impact of the algorithm were evaluated. RESULTS: The combined use of CRD and an eDiary increased the hypothetical AIT prescriptions, both among AS and GP (p < .01). AIT prescription for pollen and Alternaria allergy based on anamnesis and SWE was heterogeneous but converged towards a consensus by integrating CRD and eDiary information. Doctors considered the algorithm useful and recognized its potential in enhancing traditional diagnostics. CONCLUSIONS AND CLINICAL IMPLICATIONS: The implementation of CRD and eDiary in the @IT2020-CDSS algorithm improved consensus on AIT prescription for SAR among AS and GP. The potential usefulness of a CDSS for aetiological diagnosis of SAR and AIT prescription in real-world clinical practice deserves further investigation.


Asunto(s)
Alérgenos/uso terapéutico , Conjuntivitis Alérgica/terapia , Sistemas de Apoyo a Decisiones Clínicas , Desensibilización Inmunológica/métodos , Médicos , Pautas de la Práctica en Medicina , Rinitis Alérgica Estacional/terapia , Adulto , Algoritmos , Alérgenos/inmunología , Alergia e Inmunología , Conjuntivitis Alérgica/inmunología , Femenino , Medicina General , Humanos , Inmunoglobulina E/inmunología , Masculino , Persona de Mediana Edad , Rinitis Alérgica Estacional/inmunología , Pruebas Cutáneas , Encuestas y Cuestionarios
15.
Clin Exp Allergy ; 51(4): 604-613, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33174280

RESUMEN

BACKGROUND: The measurement of specific IgE to allergenic extracts and molecules in patients with allergic rhinitis (AR) is crucial for a precise diagnosis and further immunotherapy. Companies providing in vitro diagnostic methods in allergology continuously strive for the optimization and modernization of such methods. A new generation of automated allergy tests based on chemiluminescence detection and paramagnetic microparticles is now available, with possible advantages in sample volume, cost-effectiveness and avoidance of sample-related interference. OBJECTIVES: To test whether sIgE antibody levels obtained with a new singleplex chemiluminescent method have a good agreement with the corresponding results obtained with a "gold standard" test. METHODS: We tested sera from 368 AR patients. Specific IgE sera levels (kU/L) to a comprehensive panel of 15 allergen extracts and 6 molecules were tested with ImmunoCAP® (Thermo Fisher Scientific Inc, Phadia AB, Uppsala, Sweden) and NOVEOS™ (HYCOR® Biomedical, Garden Grove, CA, USA). We evaluated the qualitative and quantitative performance of the new NOVEOS system in matching the outcome of ImmunoCAP to each of the examined allergens. RESULTS: In relation to ImmunoCAP, the overall diagnostic sensitivity and specificity of sIgE tests with NOVEOS were 90.8% (95% CI = 88.6-92.7) and 96.2% (95% CI = 93.9-97.8), respectively. These values were higher when only molecules were considered (sensitivity = 98.7% [95% CI = 96.4%-99.7%]; specificity = 94.2% [95% CI = 88.4%-97.6%]) and lower when only extracts were considered (sensitivity = 87.6% [95% CI = 84.7%-90.2%]; specificity = 97% [95% CI = 94.4%-98.6%]). Spearman's correlation between the data set of both methods for a ≥ 0.1 kU/L cut-off was 0.84 (p < .001). CONCLUSIONS: The new singleplex NOVEOS system presented good results for qualitative and quantitative comparisons when testing specific serum IgE antibodies against a range of 21 allergens. This novel immunoassay system using only 4 µl of sample per test appears to be robust and reliable and can, therefore, be used as an aid in allergy diagnosis.


Asunto(s)
Alérgenos , Inmunoglobulina E/análisis , Mediciones Luminiscentes , Rinitis Alérgica/diagnóstico , Adolescente , Adulto , Niño , Femenino , Humanos , Inmunoglobulina E/inmunología , Masculino , Persona de Mediana Edad , Rinitis Alérgica/inmunología , Sensibilidad y Especificidad , Adulto Joven
16.
Front Pediatr ; 8: 598690, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33363063

RESUMEN

Introduction and Objectives: Wheezing episodes are the first causes of doctor's consultation in preschool age. Treatment is usually administered with a metered dose inhaler (MDI) spacer. At variance, many parents and doctors prefer to use a compressor nebulizer, which cannot be easily carried. The study is aimed at testing whether a pocket mesh nebulizer has similar efficacy and acceptability than a standard MDI device. Materials and Methods: The IPAC study was a randomized, controlled, non-inferiority trial (number: 1616/2018, Ospedale Pediatrico Bambino Gesu'-IRCCS). The study had two arms: cases, using MicroAIR U100, and controls, using MDI+spacer device. Both devices were adopted for long-term treatment and for exacerbations. Follow-up was organized with clinical visits and a daily e-diary connected to an application for mobile phone. Results: One hundred patients were enrolled. The frequency of asthmatic symptoms showed a non-inferiority for MicroAIR U100 group vs. MDI. Accordingly, no significant difference was found in the average % of days with cough, wheezing, breathlessness after exercise, days lost at school, and not-programmed visits. Considering only patients with >1 day with symptoms, no significant sdifferences were found in the number of exacerbations nor in the cumulative days with symptoms. The acceptance and usability of both devices have been favorable. However, the MDI+AeroChamber® device showed better acceptability. Conclusions: Our study shows that MicroAIR U-100, a mesh nebulizer, has similar clinical efficacy but lower acceptance and usability than an MDI plus Aerochamber® in delivering therapy in preschool wheezers. Therefore, MicroAIR U-100 might be a valuable second choice, when the delivery of medication with an MDI plus Aerochamber® is not accepted, or wrongly used by the parents.

17.
PLoS One ; 15(11): e0242197, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33201892

RESUMEN

The use of mobile communication devices in health care is spreading worldwide. A huge amount of health data collected by these devices (mobile health data) is nowadays available. Mobile health data may allow for real-time monitoring of patients and delivering ad-hoc treatment recommendations. This paper aims at showing how this may be done by exploiting the potentialities of fuzzy clustering techniques. In fact, such techniques can be fruitfully applied to mobile health data in order to identify clusters of patients for diagnostic classification and cluster-specific therapies. However, since mobile health data are full of noise, fuzzy clustering methods cannot be directly applied to mobile health data. Such data must be denoised prior to analyzing them. When longitudinal mobile health data are available, functional data analysis represents a powerful tool for filtering out the noise in the data. Fuzzy clustering methods for functional data can then be used to determine groups of patients. In this work we develop a fuzzy clustering method, based on the concept of medoid, for functional data and we apply it to longitudinal mHealth data on daily symptoms and consumptions of anti-symptomatic drugs collected by two sets of patients in Berlin (Germany) and Ascoli Piceno (Italy) suffering from allergic rhinoconjunctivitis. The studies showed that clusters of patients with similar changes in symptoms were identified opening the possibility of precision medicine.


Asunto(s)
Conjuntivitis Alérgica/epidemiología , Rinitis Alérgica/epidemiología , Adolescente , Niño , Análisis por Conglomerados , Femenino , Lógica Difusa , Humanos , Masculino , Telemedicina/métodos
18.
Front Immunol ; 11: 2116, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33013892

RESUMEN

Clinical decision support systems (CDSS) aid health care professionals (HCP) in evaluating large sets of information and taking informed decisions during their clinical routine. CDSS are becoming particularly important in the perspective of precision medicine, when HCP need to consider growing amounts of data to create precise patient profiles for personalized diagnosis, treatment and outcome monitoring. In allergy care, several CDSS are being developed and investigated, mainly for respiratory allergic diseases. Although the proposed solutions address different stakeholders, the majority aims at facilitating evidence-based and shared decision-making, incorporating guidelines, and real-time clinical data. We offer here an overview on existing tools, new developments and novel concepts and discuss the potential of digital CDSS in improving prevention, diagnosis and monitoring of allergic diseases.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas/normas , Hipersensibilidad/diagnóstico , Medicina de Precisión/métodos , Pruebas Diagnósticas de Rutina , Medicina Basada en la Evidencia , Humanos , Monitoreo Fisiológico , Guías de Práctica Clínica como Asunto
19.
Ital J Pediatr ; 46(1): 105, 2020 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-32711557

RESUMEN

BACKGROUND: Digital health technologies carry the great potential of assisting physicians in making well-informed diagnostic and therapeutic decisions. In allergy care, electronic clinical diaries have been recently used to prospectively collect patient data and improve diagnostic precision. OBJECTIVE: This review summarizes the clinical and scientific experience we gathered over 10 years of using a digital platform for patients suffering from seasonal allergic rhinitis. METHODS: The mobile application and back-office of AllergyMonitor (TPS software production, Rome, Italy) enable patients to record their daily allergy symptoms as well as drug and immunotherapy intake plus possible side effects in a customizable way. The results can be accessed by the patient and attending physician as concise reports via a smartphone or computer. This technology has been used in several clinical studies and routine practice since 2009. RESULTS: Our studies showed that A) the etiological diagnosis of SAR may be supported by matching prospectively registered symptoms with pollen counts; B) it is possible to perform a short-term prediction of SAR-symptoms at individual level; C) the adherence to daily symptom monitoring can remain high (> 80%) throughout several weeks when prescribed and thoroughly explained by the treating doctor; D) the use of mobile technology can improve adherence to symptomatic drugs as well as allergen-specific immunotherapy and E) the choice of the correct symptom-severity-score is critical at patient level, but not at group level. CONCLUSION: The studies and clinical practice based on the use of AllergyMonitor have proven the reliability and positive impact of a digital platform including an electronic diary (eDiary) on the diagnostic precision of SAR in poly-sensitized patients as well as patient adherence to both, drug therapy and allergen immunotherapy.


Asunto(s)
Tecnología Digital , Sistemas en Línea , Rinitis Alérgica Estacional/diagnóstico , Rinitis Alérgica Estacional/terapia , Telemedicina , Humanos , Rinitis Alérgica Estacional/etiología
20.
Clin Chem Lab Med ; 58(11): 1865-1874, 2020 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-32549134

RESUMEN

Objectives Detection of allergen-specific immunoglobulin E (sIgE) is important for the diagnosis of allergy. IgE sensitization is commonly demonstrated in vivo by skin prick testing (SPT), or in vitro utilizing automated systems. Recently, HYCOR® Biomedical launched its new system for allergen sIgE testing called the NOVEOS™ Immunoanalyzer. This study aims to evaluate the analytical performance of the NOVEOS system in a bi-center study at Philipps-University Marburg (Site-1) and Charité Medical University Berlin (Site-2), respectively. Methods The analytical performance was evaluated based on the guidelines I/LA20-A3, EP5-A3, EP17-A2, EP6-A, EP7-A3, and EP9-A3 of the Clinical and Laboratory Standards Institute (CLSI). Results The conducted repeatability and within-laboratory precision tests provided acceptable performance with 3.0%-11.9% coefficient of variation across both sites. The limit of blank (LoB) and limit of detection (LoD) were <0.1 kU/L at both centers. A within-parameter linearity for all tested allergens was reported at both sites. Of note, no significant interference was observed for high levels of biotin, methylprednisolone, diphenhydramine, omalizumab, or ranitidine. Method comparison between the NOVEOS calibration and the latest World Health Organization (WHO) reference standard showed good agreement at both sites. Conclusions The results from the analytical performance of the NOVEOS allergen sIgE assay and instrument testing at both sites were comparable. Overall, a good precision and linearity as well as a detection limit <0.1 kU/L were observed, with minimal impact of common interfering substances on patient recoveries. The NOVEOS is calibrated to the latest WHO reference standard and adds benefits like a small sample size and para-magnetic microparticles that improve upon third-generation allergen sIgE assays' design and performance.


Asunto(s)
Hipersensibilidad/diagnóstico , Inmunoglobulina G/sangre , Alérgenos/inmunología , Humanos , Hipersensibilidad/sangre , Inmunoensayo/métodos , Inmunoglobulina G/inmunología , Pruebas Inmunológicas/métodos , Límite de Detección
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...